Memorial Day Sale - Up to 50% Off! Shop Now >

Find Throttle Enhancement for your Sierra 2500

Pacbrake PH+ PowerHalt Electronic Air Shut-off Valve Kit (21-26 6.6L Duramax Sierra 2500 HD)Find parts that fit my vehicle

Item HG30842
Our Price

$1,125.95 each

Military, Medical & First Responders $56.30 Available in AT Cash Rewards.
Confirm Eligibility

CONFIRM THIS FITS YOUR VEHICLE!

Select a different vehicle Help?
Update or Change Vehicle
    Create a list
    Add to New List

    Saved - View your saved items

    We're sorry. We couldn't save this product at this time.

    or use

    Shop Owners Save More! Sign up for our dealer program

      Product Information

      Features, Description, Q&A, Specs & Installation

      Features

      • Diesel Engine Runaway Can Occur When The Engine Inhales Flammable Particles Like Gas, Oil Vapors, Or Grain Dust
      • Electronic Emergency Engine Shutdown System Controls The Electronic Throttle Body Found On Most Late Model Diesel Engines
      • Closes Off Air Supply During Emergencies To Protect Operator, Vehicle, And Equipment
      • Electronically Controlled System Forces Engine Shutdown By Blocking Air Intake Path
      • Automatic Shutdown Activates If Engine Speed Exceeds Pre-Set Limit Or Via Manual Override
      • Valve Electronically Returns To Open Position After Shutdown
      • Operator Feedback Provided Through Illuminated Switch When Valve Is Closed
      • Safe And Reliable Emergency Shutdown Compatible With Diesel Engines Featuring Electronic Throttle Body
      • Shutdown Triggered Automatically Via Overspeed Signal Or Manually Via Toggle Switch
      • Valve Holds Closed For Minimum 15 Seconds After Activation And Remains Closed Until Shutdown Signal Is Cleared
      • Secondary Trip Speed Available For PTO Equipment Protection Or Anti-Theft Function
      • Includes In-Cab Toggle Switch For Manual Shutdown
      • Automatically Resets After Shutdown Condition Clears
      • Switch Light Illuminates When Valve Closes To Indicate Activation
      • Valve Resets And Switch Light Turns Off When Shutdown Signal Is Removed
      • Secondary Trip Speed Input Enables Second Emergency Shutdown Threshold For Auxiliary Equipment Or Theft Prevention
      • Five Second Grace Period When Adjusting To Lower Trip Speed
      • Plug & Play Installation With Factory Connectors And Pre-Assembled Wiring Harness
      • Typical Installation Time Under 60 Minutes
      • Easily Removable For Leased Vehicles
      • User-Friendly Fully Automatic Operation With Manual Override Capability
      • Multiple Programmable Shutdown Speeds
      • Does Not Trigger ECM Trouble Codes
      • Valve And Controller Have IP67 And IP69K Ratings For Water And Dust Resistance
      • Includes PH+ Power Guard Controller, Application Specific Harness, Power/Switch Harness, Toggle Switch Assembly, Tie Straps, And Self-Tapping Screws
      • Battery Voltage: 12 VDC Nominal (9 – 14 VDC)
      • Operating Temperature Range: -40°C To +85°C [-40°F To +185°F]
      • Vibration Resistance: 8 Grms
      • Valve Activation Duration: Minimum 15 Seconds
      • Idle Current Consumption: 17.5 mA @ 12 VDC
      • Activation Current Consumption: 9.5 A Max @ 14 VDC
      • PTO Input Signal: Ground
      • Installation Torque Range: 1.13 To 1.36 Nm [10 To 12 In-Lbf]
      • Compatible With 2021-2026 6.6L Duramax Sierra 2500 HD

      Description

      Description. Protect your life, livelihood and your vehicle with a PH+ Electronic Emergency Engine Shutdown system. Diesel engine runaway can happen whenever your engine sucks in flammable particles, such as gas and oil vapors in the air - or even grain dust. PH+ controls the electronic throttle body in the intake manifold found on most late model diesel engines and will close off the air supply in emergency situations.

      Key Features and Benefits

      • Automatic Emergency Engine Shutdown
      • Plug and play install - factory connectors and pre-built wiring harness
      • Can be installed in 60 minutes or less
      • Will not set ECM trouble codes
      • IP67 waterproof rating
      • Auto resets after shutdown
      • In-cab switch for manual shutdown included
      • Secondary trip speed for Power Takeoff (PTO) applications
      • Easily change between multiple built-in shut-off speeds
      • Use for truck security by setting a low trip speed
      • Have a leased truck? No worries! Unit can be easily removed
      • Warranty: 24-months / 24,000 miles or 39,000 kms

      Application. This Pacbrake PH+ PowerHalt Electronic Air Shut-off Valve Kit is designed to fit 2021-2026 6.6L Duramax GMC Sierra 2500 HD models.

      Pacbrake C50362A

      CA Residents: WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

      Installation & What's in the Box

      Installation Info

      Installation Time

      (approx) 1 Hour

      Difficulty Level:

      Simple installation for anyone.

      Installation Guides

        No guide available for this part yet.

      What's in the Box

      • PH+ PowerGuard Controller
      • PowerHalt Power/Switch Harness
      • PowerHalt Application Specific Harness
      • Toggle Switch Assembly
      • Tie Straps
      • Self-Tapping Screws
      • Switch Cover
      • Switch Label
      • Switch Decal

      Tech Specs

      Questions & Answers

      No questions about this product yet. Ask the First Question

      Will It Fit My Sierra 2500

      • 6.6L V8 Duramax - 21, 22, 23, 24, 25, 26